how to check battery status on slc 505

The SLC 5/05 Programmable Logic Controller (PLC) is often referred to as the workhorse of many industrial systems because of its ability to perform well under harsh conditions. It uses a battery to store essential memory, configuration, and program data during an interruption in the power supply. It is important to keep the PLC battery healthy because you do not want unexpected loss of data, or worse, system downtime.

This blog will provide you with detailed guidance on how to check the battery status of your SLC 5/05. We will take you step by step through the physical inspection, software checks, and manual voltage testing, sharing some best practices for maintaining optimal battery performance.


What is SLC 5/05 Battery

The battery of the SLC 5/05 is responsible for keeping the volatile memory alive in cases of power loss. This memory contains system configurations, ladder logic programs, and other runtime data. Without a working battery, any unsaved data is lost. This situation can lead to a breakdown in current operations since reprogramming is time-intensive.

Some signs that the battery may be failing include:

  • Battery Low Indicator: The PLC’s status LED or diagnostic messages in the software will tell you that it is time to change the battery.
  • Unexpected System Resets: If the battery cannot retain memory, then it will lose configurations after every power cycle.
  • Physical Wear: Leakage, corrosion, or swelling means a replacement is overdue.

With all this knowledge, you can now manage your PLC battery health proactively.


Allen-SLC-505-Battery

Step-by-Step Guide to Checking Battery Status

Let’s take a look at the steps to check the battery status on your SLC 5/05.


Tools and Preparations

Before you start, make sure that you have the following tools and materials:

  • A laptop with the RSLogix 500 software.
  • Communication cable to connect to the PLC.
  • Multimeter (for voltage testing).

Safety Precautions

  • Always back up the PLC’s program using RSLogix 500 before you handle the battery.
  • Wear appropriate safety gear, especially if you find any signs of battery damage.

Step 1. Physical Inspection

Begin by identifying the location of the battery. It is usually found in the front panel of an SLC 5/05 PLC. Remove the battery cover and look through the battery. Examine for the following:

  • Damage: Check for cracks, bulging, or other forms of wear.
  • Corrosion: Check for any residue or rust signs on the terminals.
  • Leakage: The presence of chemical spills emanating from the battery.

If you find such signs, replace the battery in order to escape further damage.


Step 2. Using RSLogix 500 Software

  • Use a communication cable to connect your laptop with 5/05 SLC.
  • Once installed, launch RSLogix 500 and connect it to the PLC.
  • Select the dimensions of the foliage or the status portion.
  • Search for warnings such as Battery low or Replace battery soon.
  • Record any warnings or error messages for further action.

This method will help you check the battery’s status and health quickly with apparent details of what to do next.


Step 3. Manual Voltage Check

  • Before taking out a battery make sure to power the PLC off properly.
  • Make sure the multimeter is set to measure direct current.
  • Make sure to place one of the probes at one of the terminals at the battery And do the same with the other probe on the other terminal of the battery .
  • The positive probe of the battery should be placed on the red terminal. The negative probe of the battery should be placed on the black terminal.
  • The voltage should then be compared with the voltage that the manufacturer recommends. In most cases, a newly bought battery recommends 3 volts or higher.

If the measurement is less than what’s needed, replace that battery, since it can be a risk while operational.


When to Replace the SLC 5/05 Battery

A battery replacement is due when:

  • The voltage drops below the acceptable range during manual testing.
  • The RSLogix 500 diagnostics repeatedly show a low battery warning.
  • The battery is over three years old, regardless of visible signs, as its performance may degrade.

Use replacement batteries from the manufacturer or a certified company for better performance and appropriate fitting of the battery. The typical replacement procedure consists of powering off the PLC correctly, taking out the old battery, and inserting the new battery in the correct way.


SLC-5-05-Battery-Status


Troubleshooting Common Battery Issues

Even with regular checks and replacements, you can still come across occasional problems with the SLC 5/05 battery. Below are common problems faced and steps for dealing with them:

  1. PLC Doesn’t Recognize the New Battery

After replacing the battery, the PLC might fail to detect it. This is usually a result of damaged connection wires. In such instances, try the following steps:

  • Look for battery terminals that can have rust or dirt build-up that interferes with a poor electrical connection. Clean it thoroughly with a soft or wet cloth.
  • Make sure the negative and positive ends of the battery coincide correctly with the markings in the compartment of the battery and secure it firmly in place.

These simple adjustments often resolve detection issues.

  1. Corrosion in the Battery Compartment

Rust can accumulate over time, especially if the battery has leaked or if the environment is humid. This can interfere with the battery’s performance. To fix this:

  • Carefully remove the battery and clean the compartment using a non-conductive cleaning solution, such as isopropyl alcohol or a specialized electronics cleaner.
  • Allow the area to dry completely before inserting the new battery to prevent short circuits or further corrosion.

Regular inspection and cleaning help prevent recurring corrosion issues.

  1. Resetting the PLC After Battery Replacement

If the PLC doesn’t return to normal operation after replacing the battery, the issue may lie with its memory or settings. Here’s what to do:

  • Reload the saved program using RSLogix 500 to restore the PLC’s configurations. This step ensures that the system is synchronized and ready to operate.
  • Double-check that all settings, such as IP configurations and ladder logic, have been restored correctly.

These troubleshooting steps will help resolve most battery-related issues, ensuring the reliable operation of your SLC 5/05 PLC.


Best Practices for Maintaining SLC 5/05 Battery Health

  • Regular Checks: Inspect the battery and perform diagnostics every six months.
  • Backup Plans: Always maintain a recent backup of the PLC program.
  • Proper Storage: Store the PLC in a cool, dry environment to prevent premature battery wear.

Following these practices minimizes the risk of unexpected issues and extends the battery’s lifespan.


Conclusion

Monitoring the battery status of your SLC 5/05 is critical to maintaining uninterrupted operation and data integrity. By following the steps outlined—physical inspection, software diagnostics, and manual voltage testing—you can ensure your PLC’s battery health is always in check.

Proactive maintenance, combined with timely replacements and adherence to best practices, ensures your PLC continues to perform reliably. Don’t wait for warning lights—take charge of your system’s battery health today!